The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Malin Alsved

Malin Alsved

Postdoctoral Fellow

Malin Alsved

Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals : Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance

Author

  • Sara Thuresson
  • Carl Johan Fraenkel
  • Sviataslau Sasinovich
  • Jonathan Soldemyr
  • Anders Widell
  • Patrik Medstrand
  • Malin Alsved
  • Jakob Löndahl

Summary, in English

BACKGROUND: Transmission of coronavirus disease 2019 (COVID-19) can occur through inhalation of fine droplets or aerosols containing infectious virus. The objective of this study was to identify situations, patient characteristics, environmental parameters, and aerosol-generating procedures (AGPs) associated with airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus.

METHODS: Air samples were collected near hospitalized COVID-19 patients and analyzed by RT-qPCR. Results were related to distance to the patient, most recent patient diagnostic PCR cycle threshold (Ct) value, room ventilation, and ongoing potential AGPs.

RESULTS: In total, 310 air samples were collected; of these, 26 (8%) were positive for SARS-CoV-2. Of the 231 samples from patient rooms, 22 (10%) were positive for SARS-CoV-2. Positive air samples were associated with a low patient Ct value (OR, 5.0 for Ct <25 vs >25; P = .01; 95% CI: 1.18-29.5) and a shorter physical distance to the patient (OR, 2.0 for every meter closer to the patient; P = .05; 95% CI: 1.0-3.8). A mobile HEPA-filtration unit in the room decreased the proportion of positive samples (OR, .3; P = .02; 95% CI: .12-.98). No association was observed between SARS-CoV-2-positive air samples and mechanical ventilation, high-flow nasal cannula, nebulizer treatment, or noninvasive ventilation. An association was found with positive expiratory pressure training (P < .01) and a trend towards an association for airway manipulation, including bronchoscopies and in- and extubations.

CONCLUSIONS: Our results show that major risk factors for airborne SARS-CoV-2 include short physical distance, high patient viral load, and poor room ventilation. AGPs, as traditionally defined, seem to be of secondary importance.

Department/s

  • Ergonomics and Aerosol Technology
  • LTH Profile Area: Nanoscience and Semiconductor Technology
  • LTH Profile Area: Aerosols
  • LTH Profile Area: Engineering Health
  • NanoLund: Center for Nanoscience
  • Infection Medicine (BMC)
  • Clinical Virology, Malmö
  • CCM BMC
  • Clinical Microbiology, Malmö
  • EpiHealth: Epidemiology for Health

Publishing year

2022-08-24

Language

English

Pages

89-96

Publication/Series

Clinical infectious diseases : an official publication of the Infectious Diseases Society of America

Volume

75

Issue

1

Document type

Journal article

Publisher

Oxford University Press

Topic

  • Infectious Medicine

Keywords

  • COVID-19
  • Hospitals
  • Humans
  • Physical Distancing
  • Respiratory Aerosols and Droplets
  • SARS-CoV-2
  • Viral Load

Status

Published

Research group

  • Clinical Virology, Malmö
  • Clinical Microbiology, Malmö

ISBN/ISSN/Other

  • ISSN: 1537-6591